@@ -647,6 +647,15 @@ receive pin to be permanently disabled.  Here are the steps the investigator
 
tried, including the alternate method of installation that did not require
 
the serial console:
 

	
 
However, the investigator was only able to read data from the serial port; the
 
investigator was unable to send key events via the serial port so the U-Boot
 
console could not be accessed in that way.  The investigator did find another
 
way of accessing the U-Boot console, though, which was used to complete the
 
U-Boot installation and verification.  The likely issue with the serial port was
 
initial mis-wiring of the serial connector, causing the receive pin to be
 
permanently disabled.  Here are the steps the investigator tried, including the
 
alternate method of installation that did not require the serial console:
 

	
 
\begin{itemize}
 

	
 
\item The investigator found the serial cable included was a USB serial adapter
0 comments (0 inline, 0 general)